HPE has a customer bulletin covering 14 HPE hard drive models, 4 TB to 14 TB, SATA and SAS. On older firmware they can fail at 65,536 hours of operation, which is about 7.5 years. HPE says a failed drive can't be recovered and can't be fixed by firmware afterward. HPE also says the failure can be caused by checking the drive's SMART data. So the usual first step, opening the management tool and looking at power-on hours, is the step to skip. Update the firmware first.

Free evaluation · No data, no fee · Talk directly with a technician.

This is a post about a failure we can't fix, so the useful part comes before anything breaks. If you run HPE ProLiant servers or HPE storage with 3.5-inch midline hard drives that went in around 2019 or earlier, here's what HPE's bulletin says, which models it lists, and what order to do things in.

Before you open any tool: HPE bulletin a00160576 says: "This issue may be caused from checking HDD SMART data. HPE strongly advises customers to update firmware immediately, before running any tools to query drives for Power On Hours (POH) (e.g., Smart Storage Administrator (SSA), HPE MegaRAID Storage Administrator (MRSA), etc.)." It names Linux and POSIX mode-page tools as well. On these models, don't look at power-on hours until the drive is on the fixed firmware.

What HPE's bulletin says

The document is a Customer Bulletin, severity High, document ID a00160576en_us (cross-reference SIK11339). The first version came out June 1, 2026. We read version 5, dated October 15, 2026, which added more models, part numbers, and firmware versions. Versions 2 and 3 (June 29 and August 25) added models too, so if you checked this list in the summer, check it again.

65,536 hours is 2,730 days and 16 hours of powered-on time. The count is hours the drive was powered on, not its age. A drive that has run nonstop since early June 2019 hits the count around the date of this post. A drive that sat on a shelf for a year gets there a year later.

The 14 models and their fixed firmware

From the Scope table in version 5. A drive is in scope if it's one of these models and its firmware is older than the version shown. HPE lists several part numbers (SKUs) for most models. The model number is what matters.

HPE modelCapacityInterfaceFixed firmware
MB004000GWKGV4 TBSATAHPG5
MB004000JWKGU4 TBSASHPD4
MB006000GWKGR6 TBSATAHPG5
MB006000JWKGN6 TBSASHPD4
MB008000GWAYL8 TBSATAHPG8
MB008000GWRTC8 TBSATAHPG4
MB008000JWAYH8 TBSASHPD7
MB008000JWRTD8 TBSASHPD3
MB010000GWAYN10 TBSATAHPG8
MB010000JWAYK10 TBSASHPD7
MB012000GWDFE12 TBSATAHPG6
MB012000JWDFD12 TBSASHPD5
MB014000GWUDA14 TBSATAHPG4
MB014000JWUDB14 TBSASHPD5

Same capacity doesn't mean same fix. There are two 8 TB SATA models with different fixes (HPG8 and HPG4), and two 8 TB SAS models (HPD7 and HPD3). Match the model number exactly.

Why the usual first step is the wrong one here

With an aging drive, the usual move is to open the RAID tool, pull up the drive's SMART details, and read the power-on hours. We say to do that in our post on HPE SAS SSDs that fail at a fixed hour count, because those bulletins don't warn about it. This bulletin does. HPE says checking SMART data "may" cause the failure. It names its own Smart Storage Administrator and MegaRAID Storage Administrator, plus Linux and POSIX mode-page tools. On a drive near the count, the check can be what breaks it.

So on any server that might have these drives, use the order HPE gives:

  1. Find out whether the model is in the table. The model number is printed on the drive label. If you can't pull drives, your server's purchase records or HPE support case history may list the drive part numbers, which are in the bulletin too.
  2. Make sure you have a backup you can actually restore before you change anything on a production array.
  3. Apply the fixed firmware. For eight of the models, HPE's Resolution section links Online HDD/SSD Flash Components for Windows, Ubuntu Linux, Linux, and VMware ESXi. In version 5, the Resolution section has no download entries yet for MB008000GWAYL, MB008000JWAYH, MB010000GWAYN, MB010000JWAYK, MB012000GWDFE, or MB012000JWDFD, even though they're in the Scope table with a fixed version. For those, search HPE Support for that model's drive firmware, or open a case with HPE.
  4. Then check the hours, if you still want to know.

Two things HPE's bulletin doesn't address, from our side. First, anything that polls SMART on a schedule, like smartd or a server monitoring agent, is also checking SMART. Ask HPE whether to pause it until the drives are updated. Second, don't run smartctl -a or smartctl -x on these drives "just to see." Both print power-on hours, so they read exactly what HPE says not to read.

Array degraded and some members are on the HPE list? Back up what still reads before anything else changes, then talk to us. Free evaluation, no data, no fee.

Drives that went in together hit the count together

Servers usually get a full set of drives at once, and they've been powered on the same number of hours ever since. HPE's RAID warning is about exactly that: once more drives fail than the array can tolerate, the data comes from backup. A RAID 5 survives one failed drive. If three drives from the same order reach 65,536 hours the same week, there's nothing left to rebuild from. A replacement drive installed in 2022 is three years behind the rest of the set, but the original members aren't.

If one member has already failed and the rest are on old firmware, the array is degraded and the remaining drives are close to the same count. The first job is getting the data off while it still reads. Copy it or restore it to new storage. Then deal with the firmware and the rebuild. A rebuild reads every surviving member from start to finish, which is a lot to ask of drives close to the count. Our rebuild vs. recovery post explains why that order matters.

StoreOnce has its own bulletin

HPE's StoreOnce bulletin a00163530 (version 1, September 28, 2026) is a separate document with different details. It covers two models, MB004000JWKGU (4 TB) and MB008000JWRTD (8 TB), on firmware HPD2 or earlier, in listed StoreOnce Gen3, Gen4, and Gen4+ systems. There HPE says the drives "experience an irreversible failure condition following a reboot or power-cycle" once they reach about 65,536 power-on hours, and that the firmware won't recover a drive that already failed. You check the drive models and firmware in the StoreOnce GUI. The fix comes from HPE Support, referencing document ID a00163492. It isn't the same download as the server components.

A StoreOnce is usually where the backups live. If the servers and the backup appliance both have drives from the same years, check both. A backup that dies at the same time as the server it backs up is no help.

If a listed drive has already failed

HPE says the drive cannot be recovered and the firmware can't be applied after the failure. We have no case in our lab or in our public case log showing otherwise, so we won't promise a result HPE's own bulletin rules out. Here's what's still worth doing:

Where this came from

Everything about models, firmware versions, the hour count, the SMART warning, and recoverability above comes from HPE's two bulletins, a00160576 (version 5, October 15, 2026) and a00163530 (version 1, September 28, 2026), as we read them on November 24, 2026. We first saw this in a Joho no Todai summary from October 18, 2026, and checked it against HPE's text. Where the two differ, follow HPE. HPE keeps revising this bulletin, so check the live version before you act.

Desert Data Recovery is a Phoenix-area lab, founded in 2013 and now a division of ioLogik LLC. Arizona drop-off is on the locations page. Everywhere else is mail-in, and here's how to pack a drive. Call (602) 686-2622, Mon–Fri 9:00am–5:00pm.

HPE 65,536-hour hard drive bulletin FAQ

Is this the same bug as the HPE SAS SSDs that died at 32,768 or 40,000 hours?
No. Those were SAS SSDs on different HPE bulletins, and we covered them in Used Enterprise SAS SSDs Can Fail at a Fixed Hour Count. This bulletin, a00160576, covers hard drives, at 65,536 hours. The practical difference is the order of operations. With the SSDs, checking the hours first is reasonable. With these hard drives, HPE says checking can be the trigger, so the firmware goes on first.
Can I check power-on hours on these drives at all?
After the drive is on the fixed firmware, yes. Before that, HPE "strongly advises customers to update firmware immediately, before running any tools to query drives for Power On Hours (POH)." HPE's examples are Smart Storage Administrator (SSA), HPE MegaRAID Storage Administrator (MRSA), and OS mode-page tools on Linux. If you need a rough number before updating, use the date the server went into service. A drive that has been powered on nonstop since early June 2019 reaches 65,536 hours around now.
My drive model is not in the table. Am I safe?
From this bulletin, yes. HPE's scope is the listed models running firmware older than the version in the table. HPE also says that many option kits contain several HPE models, and the bulletin applies only to the models it lists. So go by the model number printed on the drive or reported by the controller, not by the kit, the server model, or the capacity. Other HPE notices exist for other drives with other hour counts. Look up the model you actually have.
The drive already failed. Can firmware or a lab bring it back?
HPE's answer is no on both counts for this issue: "After the HDD failure occurs, the HDD cannot be recovered. Also, the firmware update cannot be applied to address the issue after the failure." We have not had one of these drives in our lab, our public case log has no case of this failure, and we are not going to tell you we can undo what HPE says can't be undone. What can still be saved is usually somewhere else: the array's surviving members, a replica, or a backup. We'll talk that through with you for free.
What about StoreOnce backup appliances?
HPE has a separate StoreOnce bulletin, a00163530. It covers MB004000JWKGU (4 TB) and MB008000JWRTD (8 TB) on HPD2 firmware or earlier in listed Gen3, Gen4, and Gen4+ systems. There, HPE says the drives fail after a reboot or power-cycle once they're near 65,536 power-on hours. Firmware for StoreOnce comes from HPE Support, referencing document ID a00163492. Don't use the server procedure on a StoreOnce.
Do you have a case like this?
Not this bug. Our HPE SmartArray case was an HPE server with 1.8 TB 10K SAS drives, which are not on this list. Those drives failed mechanically. They had years of runtime from a data center before that server, and members had dropped out months before anyone replaced them. We also don't publish a success rate.

If your servers have drives from that table, update the firmware before you look at the hours. If an array is already down past its fault tolerance and there's no backup, don't force it or rebuild it. Start with a free evaluation and we'll tell you straight what's worth trying.