ACCEPTING CASES · MON–FRI 9:00AM–5:00PM
Certified Data Recovery Professional · Phoenix, AZ ☎ (602) 686-2622

Dell Says Update Your SN8000S SSD Firmware? Back Up First. If It Already Shows "Error Occurred," the Update Isn't the Fix.

If your Dell or Alienware has a SanDisk/WD PC SN8000S SSD and Dell tells you to update its firmware, do it, but back up first. That order matters. The update is for a drive that still works. If the drive already shows "Error Occurred" in the BIOS or has vanished from Windows, stop. Flashing firmware isn't a recovery step, and your data is still on that drive.

Free evaluation · No data, no fee · Talk directly with a technician.

The PC SN8000S is a SanDisk (formerly Western Digital) NVMe SSD that ships in a lot of current Dell and Alienware machines. Dell has published firmware updates for it, and at least one owner says Dell emailed him to install one. This post covers what we could verify, what we couldn't, and what to do in each case: the drive still works, or it's already gone. We already wrote about an SSD that vanishes from BIOS and about SSD firmware faults in general. This one is specific to this drive.

What we could verify, and what we couldn't

Verified on Dell's site: Dell's KB 000379457 lists the SN8000S by Dell part number and names the fixed firmware: 6301.2103, A03 or later for the regular drive (DPN DVK06, H1CNH, 50KMR) and 6311.2103, A03 or later for the self-encrypting SED version (DPN N1KT3, 0XH6P, 4PF9M, 4FN86). Before updating, the KB says to back up all personal data and plug laptops into AC power. Be aware that this KB is about a different bug: SQL Server failing to install because the drive reports the wrong physical sector size. It isn't about drives that disappear.

Verified on LVFS: the Linux firmware service lists newer Dell SN8000S builds: 63012106 for the 2 TB drive and 63112106 for the 4 TB SED. "Or later" really does mean later.

Owner-reported, not found on a Dell page: an owner of an Alienware m18 R2 posted on HDD Guru on October 3, 2026 that Dell emailed him in May. He quotes the email as saying these systems "may experience a hard drive not recognized error, which can lead to drive failure," and recommending "version 6301.2103, A03, or later." He also says he understood the fault to be triggered when the drive comes out of low-power mode. We couldn't find either claim on a public Dell page, so treat both as his account, not Dell's published statement.

What happened to him

His laptop had two 2 TB SN8000S drives in an Intel RAID 0. He didn't have anywhere to put 4 TB of backup, so he held off on the update in case it bricked the drives. That's an understandable fear, and backwards. Months later, Windows threw an error and restarted while he was playing a game, and the machine wouldn't boot. In the BIOS, both drives still showed their part and serial numbers, and the RAID volume showed "Normal," but each drive showed "Error Occurred." Windows Recovery couldn't see the array even with the Intel storage driver loaded. He also found a fan clogged with dust. All of this is his account. The thread doesn't say how it ended.

Two things stand out. First, a drive that reports its serial number but errors on everything else is a common way an SSD controller fails. The drive identifies itself, then can't serve data. Second, both drives failed together. With RAID 0, losing either one takes everything.

If your SN8000S still works, back up and then update. If it already shows "Error Occurred" or vanished, don't flash it, don't initialize it, and don't rebuild the RAID volume. Power it down and get an evaluation.

If the drive still works: the order that protects you

  1. Check what you have. In Device Manager or Dell SupportAssist, look for "PC SN8000S" and its firmware version. Dell's KB lists 63012102 and earlier (or 63112102 and earlier for SED) as affected by the SQL Server bug.
  2. Back up before anything else. Dell says this in its own KB. A firmware update is a write to the drive's controller. Most go fine, but "fine most of the time" isn't a plan for your only copy. If you can't afford storage for a full backup, copy what you can't replace: photos, documents, project files. That's a few hundred GB, not 4 TB.
  3. Update from Dell, for your exact system. Enter your service tag on Dell Support or use SupportAssist or Dell Command Update. Plug in AC power, and don't interrupt it.
  4. For RAID 0, think again. Two drives striped means twice the hardware that can take everything with it. If the machine came that way and you don't need the speed, a backup matters even more.
  5. Clean the fans. We can't say heat caused his failure. A laptop running hot with a clogged fan doesn't help any SSD.

If it already shows "Error Occurred" or vanished: what not to do

The forum advice he got was sound: check each drive's health, image each drive to stable storage if they'll read, rebuild the array in software from those images, and copy files from that. The catch is that his drives showed "Error Occurred." Imaging a drive whose controller won't serve data usually needs lab tools, not a USB adapter.

When it's a lab case

A working SN8000S that needs a firmware update isn't a lab case. Back it up, update it, done. It becomes lab work when the drive shows up by name but won't read, disappears entirely, or was half of a RAID 0 that won't open. What we do for SSD and RAID cases is work on the drive through its own controller, image each member first, and rebuild any array from the images, never from your originals. The closest job in our public case log is a two-drive WD_BLACK SN850X RAID 0 where both SSDs were weakening at once. It's a different drive and an enclosure, not a Dell laptop, so it isn't proof this one will go the same way. It shows the method: both drives imaged before anything else, and the stripe layout worked out from the images.

We'll be plain about the limit. An SSD whose controller has failed doesn't always come back. We don't publish a success rate, and we won't promise anything before an evaluation. The technician on your case will tell you what they find before you pay for anything.

Desert Data Recovery is a Phoenix-area lab, founded in 2013 and now a division of ioLogik LLC. Arizona drop-off is on the locations page. Everywhere else is mail-in. If you're sending a pair from a RAID, pack them like this and label which slot each came from. Call (602) 686-2622, Mon–Fri 9:00am–5:00pm.

Dell SN8000S firmware FAQ

Is the Dell email about the SN8000S real?
We haven't been able to find the email's wording on a public Dell page. What we have is an owner on the HDD Guru forum quoting a Dell email he says he got in May 2026: "Dell Technologies systems purchased with a specific SanDisk SSD may experience a hard drive not recognized error, which can lead to drive failure," with a recommendation to update to "version 6301.2103, A03, or later." The firmware versions do match a public Dell document, KB 000379457. If you got an email like this, check it against your system's page on Dell Support before running anything it links to.
Which firmware version do I need?
Dell's KB 000379457 names 6301.2103, A03 or later for the non-SED SN8000S (Dell part numbers DVK06, H1CNH, 50KMR) and 6311.2103, A03 or later for the self-encrypting SED version (N1KT3, 0XH6P, 4PF9M, 4FN86). Those are the versions the KB lists. The KB itself is about a SQL Server install error, not a drive that disappears. The LVFS firmware listing shows newer Dell builds too (63012106 for the 2 TB drive, 63112106 for the 4 TB SED). Get the package for your exact system from Dell Support, not from a third-party site.
My drive shows "Error Occurred" in the BIOS. Will the firmware update bring it back?
Don't count on it, and don't try it on the only copy of your data. A firmware update is meant to prevent the problem on a drive that still works. It has to talk to a working controller to install at all. We haven't seen Dell say anywhere that the update repairs a drive that has already failed. Writing new firmware to a controller that's already misbehaving is a risk, not a fix. If the data matters, power it down and get it evaluated first.
Can a lab just take the chips off and read them?
Not on a drive like this. On current NVMe SSDs, what's stored on the NAND chips is tied to that drive's own controller, and the SED version is self-encrypting by design. Desoldering the chips gives you data you can't read. We explain why in chip-off won't save an AES NVMe. Recovery has to go through the drive's own controller.
Both drives in my RAID 0 failed at once. Is that normal?
Same model, same firmware, same laptop, same heat, same hours. If a firmware fault or an overheating machine is behind it, both drives would get hit at the same time. The owner in the forum thread asked the same question, and nobody there could answer it. What it means for you: with RAID 0 there's no good copy to fall back on, so treat both drives as the evidence. See RAID 0 when one drive dies.

The SN8000S firmware update is for a drive that still works. Back up, then update. If the drive already shows "Error Occurred" or is gone, don't flash it or rebuild the array. Start with a free evaluation.

Request free evaluation →

Free evaluation · No data, no fee · Talk directly with a technician.